CAH05A1BG

Lead Time: 

10 Days

function

AC Overcurrent & Undercurrent

control voltage

240V AC

output

10A SPDT

TRIP DELAY

0.5 – 50 Sec

SENSING DELAY ON POWER

4 Sec

MOUNT

Two Screw Mounting

Setting Adjustment

Analog

Options

None

CURRENT RANGE

0.5 – 5A

REMOTE POTENTIOMETER 2

$120.20

Description of Function

Overcurrent Sensing: After control voltage is applied & the sensing delay on power-up (ts) is completed, the unit will begin sensing for a fault condition. A fault will occur when the monitored AC current (I) goes above the Fault Trip Current setting & remains above the Reset level for a period longer than the adjustable time delay period (t). The LED will turn ON immediately and the relay will energize after the time delay on pick-up (t) is completed. The relay will de-energize & the LED will turn OFF when the monitored AC current goes below the Reset level. Undercurrent Sensing: After control voltage is applied & the sensing delay on power-up (ts) is completed, the unit will begin sensing for a fault condition. A fault will occur when the monitored AC current (I) goes below the Fault Trip Current setting & remains below the Reset level for a period longer than the adjustable time delay period (t). The LED will turn ON immediately and the relay will energize after the time delay on pick-up (t) is completed. The relay will de-energize & the LED will turn OFF when the monitored AC current goes above the Reset level.

Function Chart

Product Overview

Features:

• Monitors single phase AC current
• Detects either an Overcurrent or Undercurrent Fault (selectable)
• Built-in current transformer allows easy access & multiple loops for increased sensitivity
• Adjustable time delay on fault trip
• LED indicates fault condition
• 10A SPDT output contacts
• Encapsulated for protection in harsh environments.
• Pilot Duty rating

Enclosure Style:

Encapsulated
Configuration / Contact Rating:
SPDT 10A @ 240V AC / 8A @ 28V DC , 1/4HP @ 120/240V AC, B300
Application Information:
• Voltage Tolerance: +10/-15% of nominal at 50/60 Hz
• Load (Burden): 2 VA
• Current Sensing:
Range: 0.5-5A
Type: Toroidal, through hole wiring
Setting Accuracy: Min: +0%, -50%; Max: +10%, -0%
Maximum Allowable Current: Steady-25A Turns; 150A Inrush for 10 Seconds
Trip Point Hysteresis: -5% Overcurrent sensing +5% Undercurrent sensing
Response Times:
Time Delay on Reset (Relay OFF): 100ms
Reset Time: 400ms
• Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
• Temperature:
Operating: -28° to 65° C (-18° to 149° F)
Storage: -40° to 85° C (-40° to 185° F)
• Mounting: Surface mount with two (2) #6 screws.
• Termination: 0.25″ male quick-connect termainals
Approvals:

Product Reviews

Do you have experience with this product? Leave us a review!
Add a review
CAH05A1BG CAH05A1BG
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
0.0
Based on 0 reviews
5 star
0%
4 star
0%
3 star
0%
2 star
0%
1 star
0%
0 of 0 reviews

Sorry, no reviews match your current selections