PMP Series

May not be exact product – for reference only.

PMPU-X

Lead Time: 

7 Days

Protection

Phase Loss, Phase Reversal, Phase Unbalance, Undervoltage, & Overvoltage

Nominal Voltage

190-500V AC

output

5A SPDT + SPNO

Time Delay on Fault

0.3-30 Sec

Restart Delay

1-300 Sec

mount

8-Pin Socket

Setting Adjustment

Analog

Options

None

Monitored Voltage

156-550V AC

$106.18

Description of Function

When the proper 3-phase line voltage is applied to the unit and the phase sequence (rotation) is correct, the relay is energized after the Restart Delay is completed. Any one of five fault conditions will de-energize the relay after a delay. Re-energization is automatic upon correction of the fault condition. A bi-color status LED indicates normal condition and also provides specific fault indication to simplify troubleshooting.

Function Chart

Product Overview

Features:

• Additional SPNO contact for signaling secondary systems
• Protects against phase loss, phase reversal, phase unbalance, undervoltage, overvoltage & rapid cycling
• True RMS voltage measurement ensures accurate sensing across more applications
• Retains fault indication and continues monitoring all voltages even with a lost phase
• Full fault indication on top of unit for easy troubleshooting
• Manual reset option works with external switch to reset the relay from outside the enclosure
• 5A SPDT + 5A SPNO contacts

Enclosure Style:

Plug-in
Configuration / Contact Rating:
SPDT + SPNO 5 A @ 277V AC / 5A @ 30V DC, 1/3 HP @ 120/240V AC, B300
Application Information:
• Power Consumption: Less than 40 VA
• Undervoltage: Adjustable from 80-95% of the line voltage setting. Unit will reset at +3% of the Undervoltage trip setting
• Overvoltage: Fixed at 110% of the line voltage setting. Unit will reset at 107% of the line voltage setting
• Phase Unbalance: Adjustable from 2-10% unbalance
• Response Times:
Restart: 1-300 seconds adjustable
Drop-out Due to:
Phase Loss & Reversal: 100ms Fixed
Phase Unbalance: 0.3 – 30 Seconds Adjustable
Undervoltage: 0.3 – 30 Seconds Adjustable
Overvoltage: 0.3 – 30 Seconds Adjustable
• Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
• Temperature:
Operating: -28° to 65°C (-18° to 149°F)
Storage: -40° to 85°C (-40° to 185°F)
• Reset: Resets automatically after completion of the restart delay
Approvals:

Product Reviews

Do you have experience with this product? Leave us a review!
Add a review
PMPU-X PMPU-X
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
0.0
Based on 0 reviews
5 star
0%
4 star
0%
3 star
0%
2 star
0%
1 star
0%
0 of 0 reviews

Sorry, no reviews match your current selections