May not be exact product – for reference only.

RT26B-04

Lead Time: 

10

Function: 

Memory Disabled

Control voltage:

120V AC

output:

10A SPDT

timing range:

0.2-5 SEC

$116.04

Description of Function

Upon application of input voltage, the time delay (t) begins. If a reset signal is applied during time delay (t), the time delay (t) is reset. At the end of time delay (t), the output relay is energized and the N.C. contact opens. If a reset signal is applied after time delay (t) has elapsed, time delay (t) is reset and relay output is de-energized. Upon removal of the reset signal either during time delay (t) or after the time delay (t) has elapsed, the time delay (t) is reset to zero. The timer uses the NC contact which opens on timeout. The time delay (t) and relay status are retained using non-volatile memory in the event of a power loss using the RESET function. The RESET (NO MEMORY) function operates in the same manner except that time delay (t) and relay status are not retained in the event of a power loss.

Description of Function

Product Overview

Features:

Compact design saves panel space Encapsulated for harsh environments Easy surface mount installation with a single bolt or screw Retains timing sequence in the event of power loss (optional: memory enabled or memory disabled) LED indication for timing and relay status Variety of time ranges Onboard potentiometer for easy time delay adjustment

Enclosure Style:

Encapsulated
Configuration / Contact Rating:
10A SPDT
Application Information:
Voltage Tolerance: AC Operation, +10/-15% of nominal at 50/60 Hz Load (Burden): Maximum of 2 VA for all voltages Setting Accuracy: Maximum Setting, +5%, -0% Minimum Setting, +0%, -50% Repeat Accuracy: (constant voltage and temperature) +/-0.1% or +/- 0.04 seconds, whichever is greater Reset Time: 100ms Start-up Time: (Time from when power is applied until unit is timing): 0.05 Seconds Maintain Function Time: (Time unit continues to operate after power is removed): 0.01 Seconds Minimum Required Trigger Switch Closure Time: 50 ms Temperature: Operating, -28° to 65°C (-18° to 149°F) Storage, -40° to 85°C (-40° to 185°F) Output Contacts: 10A @ 240VAC / 7A @ 28VDC SPNO, 1/4hp @ 120VAC (N.O.) Life: Mechanical, 10,000,000 operations; Full Load, 100,000 operations Mounting: Surface with one #8 or #10 screw or on 35mm DIN rail with Macromatic P/N 70500 Termination: 0.25” male quick-connect terminals
Approvals:
UL #: E109466

Operations

Upon application of input voltage, the time delay (t) begins.  If a reset signal is applied during time delay (t), the time delay (t) is reset.  At the end of time delay (t), the output relay is energized and the N.C. contact opens.  If a reset signal is applied after time delay (t) has elapsed, time delay (t) is reset and relay output is de-energized.  Upon removal of the reset signal either during time delay (t) or after the time delay (t) has elapsed, the time delay (t) is reset to zero.  The timer uses the NC contact which opens on timeout. The time delay (t) and relay status are retained using non-volatile memory in the event of a power loss using the RESET function. The RESET(NO MEMORY) function operates in the same manner except that time delay (t) and relay status are not retained in the event of a power loss.

Product Reviews

Do you have experience with this product? Leave us a review!
Add a review
RT26B-04 RT26B-04
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
0.0
Based on 0 reviews
5 star
0%
4 star
0%
3 star
0%
2 star
0%
1 star
0%
0 of 0 reviews