THL

Series

May not be exact product – for reference only.

THL-1024U-07

Lead Time: 

10

Days

Universal: 24-240V AC and 12-48V DC

Consult Factory

Consult Factory

None

Encapsulated

1A normally open (solid state)

Voltage Tolerance: AC Operation: +10/-25% of nominal at 50/60 Hz; DC Operation: +10/-15% of nominal. Load (Burden): Maximum of 1 VA for all voltages Setting Accuracy: Maximum Setting (Adjustable): +5%, -0%; Minimum Setting (Adjustable): +0%, -50%; Fixed Time Delay: +2% or 50ms, whichever is greater Repeat Accuracy (Constant Voltage & Temperature): +0.1% or + 0.04 seconds, whichever is greater Reset Time: 50ms Output Contacts: Normally Open Solid State 1A Continuous, 10A Inrush @ 65° C, Pilot Duty Life: No predictable failure if used within operating parameters. Leakage Current (OFF-State): <5 ma @ 240VAC Minimum Load Current: 20ma Effective Voltage Drop (ON-State): Maximum 3V @ 1A for all voltages Temperature: -40° to 65°C (-40° to 149°F)

https://macromatic.com/wp-content/uploads/2024/02/approval-ce.jpg-2.webp

10

THL

Function: 

On Delay

CONTROL VOLTAGE

Universal: 24-240V AC and 12-48V DC

output

1A normally open (solid state)

TIMING RANGE

0.03 – 30 seconds

TIMING RANGE 2

None

MOUNT

Encapsulated

TIMING ADJUSTMENT

Analog

STANDARD MODIFICATIONS

None

REMOTE POTENTIOMETER

Consult Factory

REMOTE POTENTIOMETER 2

Consult Factory

Description of Function

Upon application of input voltage, the time delay (t) begins. At the end of the time delay (t), the output is energized. Input voltage must be removed to reset the time delay relay & de-energize the output.

Function Chart

Product Overview

Features:

Available as either a multifunction version with 16 functions built-in or as individual function versions DIP-Switches for accurate digital set of time delay (multi- & single-function) & selection of function (for multi-function only) Programmable delay of 50ms – 10,230 hours (multi-function) or 100ms – 1,023 hours (single-function) LED indicates relay status Pilot Duty Rating

Enclosure Style:

Encapsulated 2″ x 2″ enclosure with single screw mounting
Configuration / Contact Rating:
Normally Open / Solid State 1A Continuous, 10A Inrush @ 65° C
Application Information:
Voltage Tolerance: AC Operation: +10/-25% of nominal at 50/60 Hz; DC Operation: +10/-15% of nominal. Load (Burden): Maximum of 1 VA for all voltages Setting Accuracy: Maximum Setting (Adjustable): +5%, -0%; Minimum Setting (Adjustable): +0%, -50%; Fixed Time Delay: +2% or 50ms, whichever is greater Repeat Accuracy (Constant Voltage & Temperature): +0.1% or + 0.04 seconds, whichever is greater Reset Time: 50ms Output Contacts: Normally Open Solid State 1A Continuous, 10A Inrush @ 65° C, Pilot Duty Life: No predictable failure if used within operating parameters. Leakage Current (OFF-State): <5 ma @ 240VAC Minimum Load Current: 20ma Effective Voltage Drop (ON-State): Maximum 3V @ 1A for all voltages Temperature: -40° to 65°C (-40° to 149°F)
Approvals:

Product Reviews

Do you have experience with this product? Leave us a review!
Add a review
THL-1024U-07 THL-1024U-07
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
0.0
Based on 0 reviews
5 star
0%
4 star
0%
3 star
0%
2 star
0%
1 star
0%
0 of 0 reviews

Sorry, no reviews match your current selections