• Voltage Tolerance: +10/-15% of nominal at 50/60 Hz
• Load (Burden): 1 VA
• Setting Accuracy:
Maximum Setting (Adjustable): +5%, -0%
Minimum Setting (Adjustable): +0%, -50%
Fixed Time Delay: ±2% or ±50ms, whichever is greater
• Repeat Accuracy: ±0.1% or ±0.04 seconds, whichever is greater
• Reset Time: 0.1 Seconds
• Life: No predictable failure if used within operating parameters
• Leakage Current (OFF-State): <5 mA @ 240VAC
• Minimum Load Current: 20mA
• Effective Voltage Drop (ON-State): Maximum 1.6V @ 1A for all voltages
• Temperature:
Operating: -28° to 65°C (-18° to 149°F)
Storage: -40° to 85°C (-40° to 185°F)
• Mounting: Surface with one #8 or #10 screw and a maximum tightening torque of 15 in-lbs
• Termination: 0.25″ male quick-connect terminals