Function

Repeat Cycle (On 1st)

CONTROL VOLTAGE

12-125V DC

output

1A SPNO (Solid State)

TIMING RANGE

10 – 1,000 Min

TIMING RANGE 2

3 – 300 Sec

MOUNT

Single Screw Mounting

Setting Adjustment

Analog

Options

None

REMOTE POTENTIOMETER

Consult Factory

REMOTE POTENTIOMETER 2

Consult Factory

$36.71

Description of Function

 Upon application of control voltage, the output is energized and the time delay (t1) begins. At the end of the time delay (t1), the output is de-energized and remains in that condition for the time delay (t2). At the end of this time delay, the output is energized and the sequence repeats until control voltage is removed. 

Function Chart

Product Overview

Features:

• Cost effective design & compact 2″ x 2″ enclosure are ideal for volume OEM applications
• Microprocessor-based design for reliable performance & maximum flexibility
• Encapsulated for protection against harsh environments
• Output rated 1A continuous/10A inrush is perfect for high duty cycle/long life applications
• Onboard and/or remote adjustable or fixed time delays from 0.01 seconds to 100 hours
• Built in load suppression eliminates need for separate protection

Enclosure Style:

Encapsulated
Configuration / Contact Rating:
SPNO / Solid State 1A Continuous, 10A Inrush @ 65° C
Application Information:
• Voltage Tolerance: +10/-15% of nominal
• Load (Burden): 1 VA
• Setting Accuracy:
Maximum Setting (Adjustable): +5%, -0%
Minimum Setting (Adjustable): +0%, -50%
Fixed Time Delay: ±2% or ±50ms, whichever is greater
• Repeat Accuracy: ±0.1% or ±0.04 seconds, whichever is greater
• Reset Time: 0.1 Seconds
• Life: No predictable failure if used within operating parameters
• Leakage Current (OFF-State): <5 mA @ 240VAC
• Minimum Load Current: 20mA
• Effective Voltage Drop (ON-State): Maximum 1.6V @ 1A for all voltages
• Temperature:
Operating: -28° to 65°C (-18° to 149°F)
Storage: -40° to 85°C (-40° to 185°F)
• Mounting: Surface with one #8 or #10 screw and a maximum tightening torque of 15 in-lbs
• Termination: 0.25″ male quick-connect terminals
Approvals:

Operations

Over/Under Voltage Relays provide protection to equipment where either an over or under voltage condition is potentially damaging. They are designed to operate when the operating voltage reaches a preset value and drop-out when the operating voltage drops to a level below the preset value.

Adjust the pick-up voltage setting (Umax) between the full range as shown on the product nameplate. Then adjust the drop-out voltage setting (Umin) between 75% and 95% of the pick-up setting. The relay energizes (and the LED is Red) when the monitored voltage is above the pick-up setting for a period longer than the fixed pick-up time delay of 0.5 seconds. The relay de-energizes (and the LED is Green) when the monitored voltage is below the drop-out setting for a period longer than the drop-out time delay (t), which is adjustable between 0.1-10 seconds. 

Product Reviews

Do you have experience with this product? Leave us a review!
Add a review
THS-1514D-37-12 THS-1514D-37-12
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
0.0
Based on 0 reviews
5 star
0%
4 star
0%
3 star
0%
2 star
0%
1 star
0%
0 of 0 reviews

Sorry, no reviews match your current selections