THS Series

May not be exact product – for reference only.

THS-1514D-37-16

Lead Time: 

10

Days

Function: 

Repeat Cycle (On 1st)

CONTROL VOLTAGE

24-240V AC

output

1A Normally Open (Solid State)

TIMING RANGE

10 – 1, 000 Min

TIMING RANGE 2

0.6 – 60 Min

MOUNT

Encapsulated

TIMING ADJUSTMENT

Analog

STANDARD MODIFICATIONS

None

REMOTE POTENTIOMETER

Consult Factory

REMOTE POTENTIOMETER 2

Consult Factory

$77.88

Description of Function

 Upon application of input voltage, the output is energized and the time delay (t1) begins. At the end of the time delay (t1), the output is de-energized and remains in that condition for the time delay (t2). At the end of this time delay, the output is energized and the sequence repeats until input voltage is removed. 

Function Chart

Product Overview

Features:

Cost effective design & compact 2″ x 2″ enclosure are ideal for industrial applications Microprocessor-based design for reliable performance & maximum flexibility Encapsulated for protection against harsh environments Normally Open output rated 1A continuous/10A inrush is perfect for high duty cycle/long life applications Universal input voltage of 24-240VAC or 12-125VDC Onboard & remote adjustable or fixed time delays from 0.01 seconds to 100 hours Pilot Duty Rating

Enclosure Style:

Encapsulated 2″ x 2″ enclosure with single screw mounting
Configuration / Contact Rating:
Normally Open / Solid State 1A Continuous, 10A Inrush @ 65° C
Application Information:
Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz DC Operation: +10/-15% of nominal. Load (Burden): Maximum of 1 VA for all voltages Setting Accuracy: Maximum Setting (Adjustable): +5%, -0%; Minimum Setting (Adjustable): +0%, -50%; Fixed Time Delay: +2% or 50ms, whichever is greater Repeat Accuracy (Constant Voltage & Temperature): +0.1% or + 0.04 seconds, whichever is greater Reset Time: 50ms Output Contacts: Solid State 1A Continuous, 10A Inrush @ 65o C Life: No predictable failure if used within operating parameters. Leakage Current (OFF-State): <5 mA @ 240VAC Minimum Load Current: 20mA Effective Voltage Drop (ON-State): Maximum 3V @ 1A for all voltages Temperature: -28° to 65°C (-18° to 149°F)
Approvals:

Operations

The cost effective design and compact size of the THS Series make them the ideal choice for many industrial applications. They utilize a microprocessor-based design for reliable performance & maximum flexibility. A Normally Open output rated 1A continuous & 10A inrush is perfect for high duty cycle/long life applications. All products are encapsulated for protection in harsh environments. Choose between adjustable or fixed time delays, either onboard or remote.

Product Reviews

Do you have experience with this product? Leave us a review!
Add a review
THS-1514D-37-16 THS-1514D-37-16
Rating*
0/5
* Rating is required
Your review
* Review is required
Name
* Name is required
0.0
Based on 0 reviews
5 star
0%
4 star
0%
3 star
0%
2 star
0%
1 star
0%
0 of 0 reviews

Sorry, no reviews match your current selections