PERCENTAGE TIMERS
PTA Series Percentage Timers provide an economical method to deliver precise and reliable repeat cycle timing for critical applications such as agricultural irrigation. A potentiometer setting determines the ON time as a percentage of the total ON/OFF cycle time. Seven fixed total cycle times are available in seconds, minutes, and hours.
Accurate Timing for Critical Applications
Setting of the time delay is easy with a rotary potentiometer. The microprocessor-based control provides reliable and accurate timing for irrigation, power systems, automation, and other industrial processes requiring economical repeat cycle timing.

PANEL CUTOUT
PTA Series Percentage Timers mount with an industry-standard panel cutout and pattern. Models are available with or without memory of timing sequence.
Function
Output
Control Voltage
Options

Need a custom engineered product? We offer engineering assistance and quick turnarounds on prototypes.
FILTER BY MODEL NUMBER
SORT BY
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70627
Options
No Memory
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70626
Options
Memory Enabled
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70625
Options
No Memory
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70624
Options
Memory Enabled
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70623
Options
No Memory
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70622
Options
Memory Enabled
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70621
Options
No Memory
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70620
Options
Memory Enabled
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70614
Options
Memory Enabled
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70619
Options
No Memory
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70618
Options
Memory Enabled
$232.01
Function:
Percentage Timer
Control Voltage:
120V AC
Output:
10A SPNO
Mount:
Pressure Clamp Screw Terminals. #12-22 AWG Wire, Solid, Stranded Wire. Recommended Tightenting Torque 7 in-lbs (12 in-lbs maximum). PTA Series Finger-safe Terminal Cover: P/N: 70617
Options
No Memory
$232.01
Frequently Asked Questions About Percentage Timers
A Percentage Timer is a time delay relay commonly used in applications such as irrigation, chemical feeding, electric heating & cooling, motors and lubrication systems. Early Percentage Timer designs were mechanical and used motors and gears to perform the timing function. The mechanical nature of these early designs also means that they are susceptible to variations in voltage and frequency. Macromatic PTA series Percentage Timers are electronic and microprocessor based. This design approach offers highly reliable, repeatable and accurate timing cycles. Changing voltage and frequency does not impact the time range or timing cycle.
Macromatic relays specify the power consumed by the device as “burden” in units of VA. Look for the burden specification in the catalog page for the specific device you have. The unit of VA(volt-amps) is essentially the same as Watts(power), current draw can be calculated in Amps by taking the VA specification and dividing by the voltage control voltage you are using to power the device.
Macromatic maintains an extensive cross reference database. Follow the link here.
Macromatic PTA series Percentage Timers are electronic and microprocessor based. This design approach offers highly reliable, repeatable and accurate timing cycles. The PTA series is available with or without memory. For applications that require memory, the standard PTA series retains timing cycle status when power is lost. When power is restored the timer continues timing without resetting the timing cycle. For applications that do not require memory, Macromatic offers the product without memory as well. The non-memory version resets the timing cycle to zero when power is removed. When power is reapplied, the timing cycle always starts at the beginning.
Percentage Timer Downloads
Knowledge Base Articles
Technical reports to answer your questions
Need Answers? Look Here.
NEED A CUSTOM ENGINEERED PRODUCT
We offer engineering assistance for you unique applications, quick turnarounds on prototypes, and the best technical support in the industry

LOCATE A DISTRIBUTOR
If you have a need for a small quantity, our Authorized Distributors have many of our products in stock, ready for immediate shipment. They can answer any questions you may have.